Bodhaine, B. A., Dutton, E. G., McKenzie, R. L., & Johnston, P. V. (1998). Calibrating broadband uv instruments: ozone and solar zenith angle dependence. Journal of Atmospheric and Oceanic Technology, 15, 916–926. 
Added by: Sarina (2011-01-03 14:39:28)   
Resource type: Journal Article
BibTeX citation key: Bodhaine1998
View all bibliographic details
Categories: Englisch = English
Keywords: Photometrie = Photometry, Ultraviolett = Ultraviolet
Creators: Bodhaine, Dutton, Johnston, McKenzie
Collection: Journal of Atmospheric and Oceanic Technology
Views: 1/1144
Views index: %
Popularity index: 0.5%
Abstract
A UV spectroradiometer was installed at Mauna Loa Observatory (MLO), Hawaii, in July 1995. This instrument has been employed to characterize several broadband UV instruments of a type commonly used to estimate erythemal irradiance at many sites around the globe. One year of clear-sky data from MLO has been analyzed for solar zenith angles (SZAs) of 5°–85°, in steps of 5°, and for total ozone values in the range 220–310 DU measured with a Dobson spectrophotometer. Because the spectral responses of various broadband instruments can be quite different, and particularly because the erythemal response defined for human skin is significantly different than that of many broadband instruments, the calibration of a broadband instrument reporting in erythemal units is strongly dependent on total ozone and SZA. When a broadband instrument is placed in the field it is necessary to know the calibration as a function of ozone and SZA to determine accurate erythemal irradiance. However, the manufacturers of broadband instruments do not generally provide information on the ozone dependence of the calibration. A procedure is described here for determining the calibration of a broadband UV instrument by comparison with a calibrated spectroradiometer. This procedure does not require precise knowledge of the spectral response of the broadband instrument. This analysis shows that if, for example, total ozone concentration decreased from 300 to 200 DU, the calibration constant of a broadband instrument should be increased by almost 20%. Therefore, the broadband instrument would significantly underestimate the increase of erythema.
Added by: Sarina  
wikindx 6.1.0 ©2003-2020 | Total resources: 1368 | Username: -- | Bibliography: WIKINDX Master Bibliography | Style: American Psychological Association (APA) | Database queries: 48 | DB execution: 0.03881 secs | Script execution: 0.10304 secs